Friday, July 27, 2012

Genetic Research Facility Will Reap the Benefits of Installing All Stainless-Steel Condensate Polisher

Kevin Preising shares how a large genetic research facility in New England will realize the benefits of a new Res-Kem single vessel Condensate Polisher. The unit will reduce the amount of iron deposits the facility was experiencing in their boiler tubes, which prolongs the life of the tubes and provides significant long-term fuel savings.
Get the full story –





For Additional Information:
For help sizing a system contact Kevin Preising
Condensate Polisher Checklist - Web Page
Condensate Polisher Checklist - Printable Version
CP Product Bulletin
View our CP System Portfolio

Friday, July 20, 2012

Greensand Filters Shipped to Western PA Water Plant

A western Pennsylvania, small private water utility, recently received four greensand filters to replace the filters that were failing.  Unable to get the original manufacturer to provide new, duplicate units, our customer found our website. 

Four New Greensand Filters with the Greensand Media Ready for Shipment to Water Utility in Pennsylvania
Four New Greensand Filters and Greensand Media Ready for Shipment to Water Utility

Because of State regulations, the systems and their operation needed to be as close to the original as possible, otherwise new permits would be required.  Since Greensand is in very, very short supply, the media was changed to Greensand Plus from the same manufacturer.  Sodium hypochlorite is used to continuously oxidize dissolved iron in the water coming into the filters.  Also, these filters are very unique because they are much shorter than we normally manufacture.  Our normal tank straightside is 60".  These tanks are 36" straightside.  

Three of the Existing Manual Greensand filters which show the tank corrosion
Three of Four Existing Manual Greensand Filters Showing Tank Corrosion

What does the company do? Public water

What is the Res-Kem water treatment application? Green sand filter to removed dissolved iron


What are the savings and/or ROI the customer wants to achieve? Not applicable.  The customer is replacing old existing system with identical system


What are the operating conditions, e.g. flow, temp, continuous, etc.? 60 gpm, Well Water Intermittent Flow

What is the system configuration, e.g. # of tanks, standby units, etc.? Four greensand filters in parallel operation


Materials of construction of tanks, piping, valves, frame, etc.? ASME Code Steel Tanks, 6’ Diameter X 36” Shell straight-side , PVC glued with manual ball valves


Type of valves and actuators? Manual ball valves


Control philosophy? Backwash as required based upon differential pressure

Special Features? Short fat tanks, required to fit tight area

For Additional Information:
Greensand Filter Technical Bulletin
Greensand Plus Technical Data
For help sizing a new filter
For help repairing or rebedding a Greensand Filter