Tuesday, May 21, 2013

Carbon and Multi-Media Filters Shipped to Eastern Pennsylvania Power Plant

Res-Kem shipped a multi-media filter and a carbon filter as pretreatment to an RO system.  Previously, this coal-fired power plant purchased a softener from Res-Kem. Also, we supply DI service vessels for post-RO polishing. 
Multi-Media Filter and Carbon Filter with Media Ready for Shipment
The general system arrangement is:

Well => Multi-Media Filter => Activated Carbon Filter => Softener => RO => Storage Tank => Service DI => To Use

What the company doesCoal fired electric generation plant
Water treatment application
Backwashable Multi-media filter
Backwashable Activated carbon filter
This water enters a previously provided Res-Kem softener which pretreats the water before entering the RO system
Operating conditions, e.g. flow, temp, continuous, etc.
The systems treat the plant’s well water.
Inlet temperature approximately 55 F
Flow rate 40 gpm
System configuration, e.g. # of tanks, standby units, etc.Single, 48” ASME code 100 psig, tank multi-media filter
Single, 48” ASME code 100 psig, activated carbon filter
Materials of construction of tanks, piping, valves, frame, media, etc.Threaded carbon steel face piping
PVC hub and laterals
Res-Karb CS1240 activated carbon
Type of valves and actuatorsCast iron, Series 42, Aquamatic diaphragm valves
Control philosophyTime clock backwashed multi-media filter using Aquamatic NXT stager/controller
Time clock backwashed activated carbon filter Aquamatic NXT stager/controller

For Additional Information:
Multi-Media Filter Brochure
Activated Carbon Filter Brochure
Industrial Water Softener Brochure
For help specifying a system

Friday, April 12, 2013

Condensate Polisher Shipped to New Jersey University

Last week, Res-Kem shipped a condensate polisher to a New Jersey university.  This condensate polisher will be installed as part of a new onsite power production facility at the university operated by an independent energy development company.  They will produce power for the university under a DBOM (Design, Build, Operate, Maintain) agreement. Excess power produced gets sold to the PJM.

Dual, Skid Mounted Stainless Steel Condensate Polisher with Headers
Customer
An independent energy development company specializing in the development, engineering, construction, start up, commissioning, operation, maintenance and management, as well as, ownership of Central Energy Centers, Renewable Energy projects and Combined Heat, Chilling and Power  Production Facilities.
General water treatment application
Two large 48”X60” sodium cycle condensate polisher for removal of contaminants in the return condensate and the return condensate from the steam driven chillers on-site
Savings and/or ROI the customer wants to achieve
Fuel and chemical saving related to the removal of iron and calcium from the condensate streams and ultimately the boiler feedwater
Operating conditions
250 gpm max, 150 gpm continuous operating at 180F
System configuration
Twin parallel / Alternating system
Materials of construction
Skid mounted
304 SS pressure vessels
Schedule 10 welded /flanged face piping
Type of valves and actuators
Bray valves with Bray actuators
System Control
Allen Bradley PLC operates the system as alternating or parallel
System schematic
Polisher collectively handles two condensate streams – return condensate from campus and condensate from steam driven chillers
Special Features
Sample cooler mounted on skid which can sample the inlet and outlet of each vessel
Inlet and outlet headers between each system on skid

Additional Information:
Listing of Condensate Polishers Built by Res-Kem
Online Catalog of Res-Kem Condensate Polishing Equipment
Condensate Polisher Technical Bulletin
Condensate Polisher Application Checklist 
For Technical Help From a Res-Kem Sales and Application Engineer

Friday, April 05, 2013

Practical Safety Training Program

Recently, the entire Res-Kem field team went through an all day practical safety training program.  The training included, Confined Space Entry, LOTO (Lock-Out Tag-Out) and JSA (Job Safety Assessment). This training is integral to Res-Kem's desire to eliminate injuries in our facilities as well as when we are working at or visiting our customer's plants.
Confined Space Entry Training

Preparing for a Confined Space Entry

 Hands-on LOTO (Lock-Out Tag-Out) Training
This program was a follow-up to our classroom program late last year.  People who attended the training were all of our field sales people, field service technicians, drivers and plant personnel.  The training took place at the Emergency Services Training Center in Sharon Hill, PA.

Contact us if you would like more information on this program.

Thursday, March 21, 2013

Water Softener Shipped to Hawaiian Resort Hotel

A water softener was shipped to a luxury resort hotel on Maui.  The system will treat the water for the hotel's laundry.
Hot Water Softener with Stainless Steel Piping and Bray Butterfly Valves
System Specifications:

Operating Temperature
140F water for laundry
System Configuration
Single hot water softener with automatic bypass
Materials of Construction
Carbon steel tank, non-code
304L stainless steel face piping
304L stainless steel internals
Cast iron Bray lug valves with 316 butterfly discs
Piping Connections
Welded
Valves and Actuators
Bray Butterfly Series 31 valves with Series 93 Air to Open/Spring Return actuators
Control Scheme
Single, time clock initiated regeneration with automatic hard water bypass

304L Stainless Steel Hub and Lateral Bottom Distributor
For Additional Information:
Res-Kem Industrial Water Softeners
For more information

Friday, February 15, 2013

Invitation to Attend "Impact of Naturally Occurring Radioactive Materials in Water on Your Carbon Filters" Seminar

You are invited to a free educational seminar on how treating drinking water with naturally occurring radioactive materials (NORM) can lead to activated carbon landfill disposal problems in as little as 7 months.

The seminar will be held March 6 at 9:00 AM at the Res-Kem-Aston, PA facility.


Why should you attend?
If your company uses activated carbon for the treatment of private well ground water for your plant's needs, remediation of ground water for VOC contamination, sulfur removal, radon reduction, this seminar has critical information that may impact the way you conduct your carbon exchange program.


Do you have is this problem? It depends.  There is a rock formation found in the region from central Pennsylvania through New England. Carbon filters can "Technically Enhance" the naturally occurring radioactive materials (TENORM) to a level exceeding landfill allowable radiation levels.
Topographical Map of Pennsylvania Showing Rock Formations
Who is presenting?
This will be about a 1.5 hour, informative, interactive presentation from:
  • Richard Croll - Radiation Health Physicist
  • Jennifer Noll - Pennsylvania DEP
  • Stephanie Carr - Calgon Carbon
Need more information?
Contact Michael Urbans
For directions to our plant in Aston, PA and agenda
Call 800-323-1983 or email

Friday, January 25, 2013

Condensate Polishing System Shipped to University in Rhode Island

A condensate polisher was shipped last week to a university in Rhode island to treat their steam condensate to save energy, reduce water usage and reduce water treatment chemical usage.
Res-Kem Dual Tank Condensate Polishers Designed to Treat a Maximum of 300 gpm

What is the Res-Kem water treatment application?Sodium cycle condensate polishing to remove iron and hardness
What are the operating conditions?Flow: Maximum of 150 gpm/vessel
Pressure: 30-100 psi
Temperature: Maximum of 200F
Continuous
What is the system configuration?Dual tank, parallel operation 30” in diameter tanks
What ion exchange resin was used?15 cubic feet of Purolite C-150 highly cross-linked macroporous cation exchange resin in each tank
Materials of construction?304 SS ASME code with a 100 psig design pressure
304 SS Hub and Lateral
Galvanized Schedule 40 Flanged and Threaded Face Piping
Type of Valves?AquaMatic High Temperature diaphragm valves

Additional Information:
Listing of Condensate Polishers Built by Res-Kem
Online Catalog of Res-Kem Condensate Polishing Equipment
Condensate Polisher Technical Bulletin
Condensate Polisher Application Checklist 
Purolite C-150 Technical Bulletin
For Technical Help From a Res-Kem Sales and Application Engineer

New Regional Service Center in Raynham, Massachusetts

On December 1st, we opened our new regional service center in Raynham, MA.  From this location, we serve Rhode Island, eastern Massachusetts & Connecticut, southern New Hampshire & Maine.

Res-Kem's New Regional Service Center in Raynham, MA

At our Raynham facility, Res-Kem:
  • Has local stock of most filter cartridges, ion exchange resin tanks (with 1 cuft, 3.6 cuft, 12 cuft, 30 cuft and 42 cuft volumes), replacement valves, valve parts, etc. used in your plant.  If you have something usual, we can maintain local inventory with our replacement part supply contracts.
  • Using our own truck fleet, provides exchange DI service for industrial, high purity and ultra high purity water production.  As required, we pick up and deliver tanks filled with activated carbon, cation resin, anion resin and/or mixed bed ion exchange resin tailored to your specific quality needs.  We can provided virgin resin exchanges and/or segregated resin handling for your most critical needs 
  • Repairs virtually all water treatment equipment from any manufacturer including RO systems, softeners, multi-media filters, carbon filters, greensand filters, EDI/CEDI equipment, UV systems and more.  
  • Monitors and maintains your water treatment equipment through PM (Preventative Maintenance)programs to virtually eliminate unplanned system shutdowns.
Need Help?:
For more information on Res-Kem's water treatment equipment


...or call 800-323-1983



Wednesday, January 16, 2013

Mighty Little Chemical Pump-Stenner ECON FP

What fits in the palm of your hand an can pump up to 30 GDP at 80 psi?  The new Stenner ECON FP pump!   The ECON FP is an extremely versatile chemical pump. 

What makes this pump special?
  • This one little pump can receive signals from either 24VAC, dry contact signal, or flow switch.
  • The Pump Control Module (PCM) is built in.
  • All wires are color coded for easy installation. 
  • The control panel is an easy to read back lit LCD.  
  • Also, it could be the safest Chemical on earth.  Why?  Normally, chemical pumps need 120-220 volts to operate. Not the FP!  Since it can accept low voltage or dry contact signals so your risk of electric shock is greatly reduced. 
  • The FP has a DC motor and electronic circuitry eliminating all the moving clutch parts found in the Classic Stenners. 
Note to plumbers Well Drillers and Water treatment professionals: 
NO MORE Jerry rigging the well switch for power.   Don't get me wrong, you still need to plug into 120 volt power, but not 220 volt.  The FP's signal options gives the installer safer power sources.  Water Treatment professionals rejoice! 

Selling Clack, Culligan, Eco-Water or Pentair products?
The FP will interface with the newer high end electronics available with these companies.  YES!  Just plug in the FP to your water softener valve, program the electronics, and the FP will run!  
What makes this pump special?


What else makes this pump so special? 
  • Even more, better, is the new tube housing assembly. Tube change outs are a breeze. Just snap off the cover and install the tube, return the cover over the tube and start pumping! 
  • Even more, more better, the FP is Stock Item.
  • Even most better, the FP costs about 35% less than a Classic Stenner combined with a PCM. 
Please note Res-Kem is a business to business company.

Please contact us at 800-323-1983 or sales@reskem.com for a product bulletin

Monday, December 03, 2012

Ultrapure Water System Starting Up at Nanotechnology Center in Philadelphia

Res-Kem supplied, to a new nanotechnology center in Philadelphia, an ultrapure water system. The start up will commence this Monday. The system is designed to produce water with three different qualities to supply:
  • 10 gpm to process cooling equipment
  • 40 gpm to laboratory benches and humidification equipment
  • 75 to 125 gpm to recirculation loop feeding process tools
Ultrapure Water System Produces a Maximum of 125 gpm of UPW
Ultrapure Water Loop Specifications
Parameter
Specification
Measurement Location
Instrument or Analysis Method
Resistivity
(% of time)
< 18.2 M-ohm-cm
(100%)
On-line
Thornton 770 MAX
TOC
< 2 ppb
On-line
Sievers 500RLE
Dissolved Oxygen
< 5 ppb average
10 ppb maximum
On-line
Swan Oxytrace
Particles
< 80 particles/liter >=0.05 micron
On-line
PMS Ultra D150
Bacteria
< 1 CFU/liter
Off-line
Low nutrient agar
Al, Ca, Co, Cr, Cu, Fe, K, Mg, Na, Ni, Pb, Zn
< 5 ppt
Off-line
IC
Boron
0.1 ppb maximum
On-line
Sievers
Dissolved Si as SiO2
< 50 ppt
On-line
Swan

The system is designed to allow for easy expansion to double the makeup rate to the ultrapure water recirculation loop.

For more Information:
Contact us if you would like presentation about this project
Modular Ultrapure Water Systems
On-line Industrial Water Treatment Catalog

Wednesday, November 21, 2012

Naturally Occurring Radioactive Material in Your Water

NORM means Naturally Occurring Radioactive Material and TENORM stands for Technically Enhanced Naturally Occurring Radioactive Material.   The USEPA states "TENORM is produced when radionuclides that occur naturally in ores, soils, water, or other natural materials are concentrated or exposed to the environment by activities, such as uranium mining or sewage treatment."  Res-Kem sees the potential for TENORM in filters and softeners treating well water in areas where naturally occurring radioactive materials NORM are found.

As a result, Res-Kem will be adding an additional test before we replace media or particularly when entering tanks. We will bring instrumentation to test for TENORM radiation.  Unfortunately, if we detect radiation, we will have to button the system back up and depart.

Again on the USEPA's website "NORM consists primarily of material containing potassium-40 and isotopes belonging to the primordial series. The principal primordial radionuclides are isotopes of heavy elements belonging to the radioactive series headed by the three long-lived isotopes uranium-238 (uranium series), uranium-235 (actinium series), and thorium-232 (thorium series). ... At background concentrations, the naturally occurring radionuclides in the uranium, actinium, and thorium series contribute about one-half of the natural background external radiation, and over 80 percent of the background including radon, to which all humans are continuously exposed."
  From a Clean Harbors bulletin on the subject, typical sources of NORM and TENORM wastes include

• Oil and gas industry
• Geothermal energy production
• Coal combustion
• Mining of uranium and metals
• Phosphate production
• Municipal water treatment
• Abandoned mines and processing facilities
• General manufacturing