Showing posts with label Valvenest using Aquamatic Valves. Show all posts
Showing posts with label Valvenest using Aquamatic Valves. Show all posts

Wednesday, June 19, 2013

Water Softener Shipped to Luxury Hotel in Delaware

Water softener for a new luxury hotel in Wilmington, Delaware was shipped from our Res-Kem Aston facility.  This system treats all the incoming Wilmington city water for the entire hotel including bathrooms, restaurant, etc.  With the special piping configuration, dual flowmeters and special Pentair NXT controller, the system operates in alternating, parallel or demand modes with simple programming changes.
 
150 gpm Continuous Water Softener System with
Carbon Steel Face Piping and Interconnecting Headers

Enduser
Water softener for a new luxury hotel in Wilmington, Delaware to treat all the incoming water for the entire building sold to through a local engineering firm
General water treatment application
Two large 48”X60” water softeners for removal of water hardness and iron.
Operating conditions
150 gpm continuous operation
System configuration
Dual ASME-Code 48” X 60” alternating softener tanks each with a separate Seametrics flowmeter
40 cu ft of 8% crosslinked softener resin per vessel
50” X 60” polypropylene brine tank
Materials of construction
Skid mounted
Internally and externally epoxy coated, carbon steel pressure vessels
Schedule 40 welded /flanged face piping
Type of valves and actuators
Cast iron, Series 42 Pentair Aquamatic diaphragm valves
System Control
Each softener has an Pentair Aquamatic NXT stager/controller
Special piping, dual flowmeters and special controller allows for alternating, parallel or demand operation with simple programming changes
Special Features
System was skid mounted to allow for lifting of unit to the top floor of the building during construction

Additional Information:
I need help sizing a water softener

Thursday, May 28, 2009

Industrial Water Softener Maintenance

Res-Kem Corp. and our sister company General Water Services offer preventative maintenance contracts for customers here in the Mid-Atlantic region. I thought it might be helpful to go over our Preventative Maintenance procedures for a commercial or industrial water softener for those of you who maintain your own water softening equipment.

Dual tank industrial water softener using multiport valves assembled by Res-kem Corp. of Aston, PA.
For an industrial water softener we suggest our customers have bi-annual visits by our technicians. It's a very simple inspection that can prevent unscheduled downtime and the associated problems. How often our customer tests the water hardness is largely determined by how critical the application is and the availability of staff. We strongly suggest testing the water hardness on a daily basis if possible.

Res-Kem service technicians do a mechanical inspection that includes the following:
Inlet and Outlet Water Hardness - When we specify a commercial or industrial water softener we are given a water analysis, the average, high and low flow rates, hours of operation, and desired end-point. It's important to note changes against the design specification. If all things are equal, seeing hard water at the outlet points to a mechanical problem with the water softener (or no salt in the brine tank). If something else has changed - flow rate is lower or higher than specified or the inlet water hardness has increased - our technician will review the data with our engineering department and discuss the problem in greater depth with the customer.


Inlet and Outlet Pressures - Pressure testing is done when the water softener is running at the design specification. If there is a high differential the water softener might be running at too high a rate. If the water softener is running at a typical flow rate, (10 – 15 gpm/ft2) and there is a high differential pressure, the resin bed could be plugging up and preventing the water from flowing through the softener correctly. The differential pressure across a softener resin bed should generally run less than 15 psig. Of course there are many factors, which can result in higher differential pressures, i.e. depth of the resin bed, design of the internal distribution, age of resin, etc.


Inlet Chlorine (in absence of carbon filter or bi-sulfite feed) - Chlorine will break down cation ion exchange resin. Exposure to significant amounts of free chlorine, "hypochlorite" ions, or other strong oxidizing agents over long periods of time will eventually break down the crosslinking. Over time the cation resin turns to mush and will plug up the bed or eventually be flushed out so there remains much less resin than required.


Check salt level in brine tank, add if necessary

Make Note of Leaks - Our technicians are trained to look carefully for that small drip. We'll fix it if possible while we're there, otherwise we will make an appointment to come back to service the problem. You should have gaskets in on hand for both the manway and handhole openings.

Make Adjustments to the Control Valve - You should have received an operating manual with the water softener which includes information about the system settings.

  • If outlet water is out of hardness specification adjustments may be necessary.

  • Verify water softener timer is set to correct time and day.

  • Recalculate how often the water softener should be regenerating based on hardness and gallons and adjust control as necessary.

  • Optional Annual Maintenance

    Valve Maintenance - There are many different types of controls and valves used on a commercial industrial water softener. In general you will need the following parts on hand to perform this service:

  • Aquamatic Valve Nest Systems - Diaphragm & Seal Kits, Internal Parts Kits, Seat Tools and Shaft Tools.
    Valve nest using Aquamatic valves for a industrial water softener

  • Fleck Top Mounted Control Systems - Upper and Lower Seal & Spacer Kits, Top Piston Kit, Lower Piston Kit.


  • Autotrol Top Mounted Control Systems - Internal parts kits. Specific kits depend on valve type.

  • Ion Exchange Resin Test - Although softener resin will last significantly longer than deionizer resin, in the presence of chlorine or other oxidants it will break down. If your water is highly chlorinated or has other contaminants such as iron, you should test the resin within 18 to 24 months of start up and every year thereafter. Otherwise, test the resin after the third year and then every year thereafter. By doing so you will know when to budget softener resin replacement as it is often a major expense.

    Friday, August 29, 2008

    Parts for Solo, Solomatic, Bruner, Brunermatic, Permutit, Aquamatic, Culligan HiFlow Multiport Valves & Others

    Routinely, Res-Kem receives requests for quotes for water treatment systems and their replacement parts. One area that frequently needs explanation is replacement parts for multi-port valves including Solo®, Solomatic®, Bruner®, Brunermatic®, Permutit®, and Aquamatic®.

    We get questions like:

    Please quote the following.:

    AQUAMATIC valves with 6 ports total. 5 ports are 3". One in the rear and 4 in cross form. The 6th port is 2", which is the regenerant inlet port.

    The fluid flowing through the valves is composed as follows:

    1) Hydrochloric acid (HCL) 32% at ambient temp.
    2) Sodium Hydroxide NaOH (caustic soda) 50% at ambient temp.
    3) Water at ambient temp.

    4) Picture of valve attached.

    Aquamatic Multi-port Valve

    Another Question:
    I have a Kisco water softener system with Aquamatic Solomatic Valves. The model number of the system is TWSKOM-300. I need replacement valves. What can I do?

    Res-Kem Solution:
    As a service company, Res-Kem frequently comes across many different water treatment systems, which have Solo, Solomatic, Bruner, Brunermatic, Permutit and Aquamatic Multiport Valves as well as other manufacturers. Unfortunately, many of these valves and controls for the valves have been discontinued or parts are extremely difficult to find, (which may be due to industry consolidation), and those parts which are available are very expensive. The Res-Kem solution is to replace the multi-port valves with a "valve nest" and an appropriate control system.

    A valve nest performs all the functions of a multiport valve using Aquamatic diaphragm, Keystone butterfly, or other valves as specified by the customer. Using a standard layout with flexibility to account for various tank sizes, a valve nest is a very cost-effective alternative to a multi-port valve.

    Valve nests can be supplied in a wide variety of materials: Cast iron valves with steel piping, Bronze valves with copper piping, plastic valves with PVC piping, stainless steel valves with stainless steel piping. They can be adapted to filters, softeners, dealkalizers, demineralizers and deionizers.